Proposed Amendment TECH-2005-08
Specifications for vented crawlspaces in the Reference
and Rated Homes
Proponent: Philip Fairey, Florida Solar Energy Center
Proposed Changes: Modify Table
303.4.1(1) to add a specification for the configuration of
crawlspaces in the Reference and Rated Homes, modify the specification
for basement and crawlspace walls to delete crawlspace walls and specify
wall insulation requirements only for conditioned basements; and delete
the column for crawlspace wall insulation in
Table 303.4.1(2).
Justification: The International Residential Code (IRC)
specifies minimum ventilation requirements for crawlspaces (IRC 408.1).
RESNET Standards should respect this code requirement. Incorporating the
proposed specification for crawlspace configuration requires that
crawlspaces be separated from basements in Table 303.4.1(1) and
eliminates the need for crawlspace wall insulation specification in
Table 303.4.1(2). The specification on basement walls is further
modified for clarity by specifying “conditioned” basements because
unconditioned basement walls are not required to be insulated to any
specific level, rather the floor of the space above an unconditioned
basement is required to be insulated in accordance with “Above-grade
floors over unconditioned spaces” requirement.
Comment period is over. View comments